I would describe myself as a very goal-oriented person who loves work in a team. Working as a Sales and Marketing Specialist with four successful years of professional achievements at multinational companies in Health Care and Pharma industry, I Got Pharma degree from one of the top rated universities in M.P.Continued with , I built my solid marketing/business pathway. As a highly motivated self starter with serious business acumen, I have been able to grow a corporation to success.
Saturday, January 1, 2011
Monday, August 23, 2010
Syllabus for GPAT-2010 Examination
Pharmacognosy & Phytochemistry - Chemistry, tests, isolation, characterization and estimation of phytopharmaceuticals belonging to the group of Alkaloids, Glycosides, Terpenoids, Ster oids, Bioflavanoids, Purines, Guggul lipids. Pharmacognosy of crude drugs that contain the above constituents. Standardization of raw materials and herbal products. WHO guidelines. Quantitative microscopy including modern techniques used for evaluation. Biotechnological principles and techniques for plant development, Tissue culture.
Pharmacology :
General pharmacological principles including Toxicology. Drug interaction. Pharmacology of drugs acting on Central nervous system, Cardiovascular system, Autonomic nervous system, Gastro intestinal system and Respiratory system. Pharmacology of Autocoids, Hormones, Hormone antagonists, chemotherapeutic agents including anticancer drugs. Bioassays, Immuno Pharmacology. Drugs acting on the blood & blood forming organs. Drugs acting on the renal system.
Medicinal Chemistry :
Structure, nomenclature, classification, synthesis, SAR and metabolism of the following category of drugs, which are official in Indian Pharmacopoeia and British Pharmacopoeia. Introduction to drug design. Stereochemistry of drug molecules. Hypnotics and Sedatives, Analgesics, NSAIDS, Neuroleptics, Antidepressants, Anxiolytics, Anticonvulsants, Antihistaminics, Local Anaesthetics, Cardio Vascular drugs - Antianginal agents Vasodilators, Adrenergic & Cholinergic drugs, Cardiotonic agents, Diuretics, Anti-hypertensive drugs, Hypoglycemic agents, Antilipedmic agents, Coagulants, Anticoagulants, Antiplatelet agents. Chemotherapeutic agents - Antibiotics, Antibacterials, Sulphadrugs. Antiprotozoal drugs, Antiviral, Antitubercular, Antimalarial, Anticancer, Antiamoebic drugs. Diagnostic agents. Preparation and storage and uses of official Radiopharmaceuticals, Vitamins and Hormones. Eicosanoids and their application.
Pharmaceutics :
Development, manufacturing standards Q.C. limits, labeling, as per the pharmacopoeial requirements. Storage of different dosage forms and new drug delivery systems. Biopharmaceutics and Pharmacokinetics and their importance in formulation. Formulation and preparation of cosmetics - lipstick, shampoo, creams, nail preparations and dentifrices. Pharmaceutical calculations.
Pharmaceutical Jurisprudence :
Drugs and cosmetics Act and rules with respect to manufacture, sales and storage. Pharmacy Act. Pharmaceutical ethics.
Pharmaceutical Analysis :
Principles, instrumentation and applications of the following: Absorption spectroscopy (UV, visible & IR). Fluorimetry, Flame photometry, Potentiometry. Conductometry and Polarography. Pharmacopoeial assays. Principles of NMR, ESR, Mass spectroscopy. X-ray diffraction analysis and different chromatographic methods.
Biochemistry :
Biochemical role of hormones, Vitamins, Enzymes, Nucleic acids, Bioenergetics. General principles of immunology. Immunological. Metabolism of carbohydrate, lipids, proteins. Methods to determine, kidney & liver function. Lipid profiles.
Microbiology :
Principles and methods of microbiological assays of the Pharmacopoeia. Methods of preparation of official sera and vaccines. Serological and diagnostics tests. Applications of microorganisms in Bio Conversions and in Pharmaceutical industry.
Clinical Pharmacy :
Therapeutic Drug Monitoring Dosage regimen in Pregnancy and Lactation, Pediatrics and Geriatrics. Renal and hepatic impairment. Drug - Drug interactions and Drug - food interactions, Adverse Drug reactions. Medication History, interview and Patient counseling.
Tuesday, July 6, 2010
People’s Institute of Pharmacy & Research Centre
Bhanpur, By-Pass road,
Bhopal-462037 (M.P.)


Most often used reagent is EDTA - EthyleneDiamineTetraAcetic acid. There are also other similar chelating agents (EGTA, CDTA and so on) used. In some of other methods Ag+ is used as a titrant for determining cyanides and Hg2+ as a titrant in Cl- determination.
Changing property of the solution is usually the concentration of the complexed substance, although in some cases it can be much more convenient to express results in terms of titrant concentration. As its concentration changes by many orders of magnitude, and is almost always smaller than 1, we use negative logarithmic scale, similar to that used in pH definition.
In the case of determination of metals detection of the endpoint is mainly based on substances that change color when creating complexes with determined metals. One of these indicators is eriochrome black T, substance that in pH between 7 and 11 is blue when free, and black when forms a complex with metal, other examples are pyrocatechin violet and murexide. It is important that formation constant for these complexes is low enough, so that titrant reacts with complexed ions first.
Iodometry
Reversible iodine/iodide reaction mentioned above is
2I- ↔ I2 + 2e-
and obviously whether it should be treated as oxidation with iodine or reduction with iodides depends on the other redox system involved.
Second important reaction used excesivelly in iodometry is reduction of iodine with thiosulfate:
2S2O32- + I2 → S4O62- + 2I-
In the case of both reactions it is better to avoid low pH. Thiosulfate is unstable in the presence of acids, and iodides in low pH can be oxidized by air oxygen to iodine. Both processes can be source of titration errors.
Iodine is very weakly soluble in the water, and can be easily lost from the solution due to its volatility. However, in the presence of excess iodides iodine creates I3- ions. This lowers free iodine concentration and such solutions are stable enough to be used in lab practice. Still, we should remember that their shelf life is relatively short (they should be kept tightly closed in dark brown bottles, and standardized every few weeks). Iodine solutions are prepared dissolving elemental iodine directly in the iodides solution. Elemental iodine can be prepared very pure through sublimation, but because of its high volatility it is difficult to weight. Thus use of iodine as a standard substance, although possible, is not easy nor recommended. Iodine solutions can be easily normalized against arsenic (III) oxide (As2O3) or sodium thiosulfate solution.
It is also possible to prepare iodine solutions mixing potassium iodide with potassium iodate in the presence of strong acid:
5I- + IO3- + 6H+ → 3I2 + 3H2O
Potassium iodate is a primary substance, so solution prepared this way can have exactly known concentration. However, this approach is not cost effective and in lab practice it is much better to use iodate as a primary substance to standardize thiosulfate, and then standardize iodine solution against thiosulfate.
Iodine gets adsorbed on the starch molecule surface and product of adsortion has strong, blue color. Exact mechanism behind adsorption and color change is not known, see for example this explanation of starch as an indicator usage.
In the presence of small amounts of iodine adsorption and desorption are fast and reversible. However, when the concentration of iodine is high, it gets bonded with starch relatively strong, and desorption becomes slow, which makes detection of the end point relatively difficult. Luckily high concentrations of iodine are easily visible, so if we are using thiosulfate to titrate solution that initially contains high iodine concentration, we can titrate till the solution gets pale and add starch close to the end point. In the case of titration with iodine solution we can add starch at the very beginning, as high iodine concentrations are not possible before we are long past the end point.
At the elevated temperatures adsorption of the iodine on the starch surface decreases, so titrations should be done in the cold.
Finally, it is worth of noting that starch solutions, containing natural carbohydrate, have to be either prepared fresh, or conserved with antibacterial agent like mercuric iodide HgI2.
It is also worth of mentioning that both solutions are not quite stable and they can not be stored for a prolonged period of time. Iodine can be lost from the solution due to its volatility, while thiosulfate slowly decomposes giving off elemental sulfur. The latter process is easily visible, as thiosulfate solutions become slightly cloudy with time.
Iodine solution
It is not difficult to prepare high purity iodine through sublimation, but - due to its volatility - iodine is difficult to weight accurately, as it tends to run away. To minimize losses it should be weight in closed weighing bottle. Iodine should be kept in a closed bottles also because it is highly corrosive and it vapor can damage delicate mechanism of analytical balance.
Commonly used solutions are 0.05M (0.1 normal).
To find out amounts of substances required to prepare the solution for a needed volume use ChemBuddy concentration calculator. Download the iodine solution preparation file. Open it with the free trial version of the concentration calculator. After opening the file enter solution volume and click on the Show recipe button. Read amounts of the substances, but don't follow the general directions. It is better to use as small initial volume of the solution as possible, that is, dissolve potassium iodide in about 1/100th of the final volume of water, before adding iodine.
To minimalize losses it is important to transfer iodine to the solution as fast as possible, or even to weight a 1% excess. Solution should be kept in dark glass bottle with grinded glass stopper and standardized every few weeks or before use.
Sodium thiosulfate solution
Sodium thiosulafte can be realtively easily obtained in a pure form, but it is quite difficult to obtain samples with known amount of water of crystallization, as the exact composition of the solid is very temperature and humidity dependent. Thus solution has to be standardized against potassium iodate KIO3 or potassium dichromate.
Commonly used solutions are 0.1M (0.1 normal).
To prepare the recipe for a needed volume of the solution use ChemBuddy concentration calculator. Download the sodium thiosulfate solution preparation file. Open it with the free trial version of the concentration calculator. After opening the file enter solution volume and click on the Show recipe button.
Small amount of carbonate added helps keep solution pH above 7, which slows down thiosulfate decomposition. Some sources also call for addition of 0.5 mL chloform per liter of the solution, to stop possible growth of bacteria that can speed up decomposition process.
Starch solution
Starch solution is used for end point detection in iodometric titration.
To prepare starch indicator solution, add 1 gram of starch (either corn or potato) into 10 mL of distilled water, shake well, and pour into 100 mL of boiling, distilled water. Stir thoroughly and boil for a 1 minute. Leave to cool down. If the precipitate forms, decant the supernatant and use as the indicator solution. To make solution long lasting add a pinch of mercury iodide or salicylic acid, otherwise it can spoil after a few days.
2% sodium bicarbonate
This solution is used for neutralization of sodium arsenite, before it is titrated with iodine solution during iodine solution standardization.
Chemical characteristics of the arsenic trioxide As2O3 make it a good candidate for a standard substance in many potentiometric methods, however, because of its toxicity it is used less and less frequently.
Arsenic oxide is dissolved in sodium hydroxide, producing sodium arsenite, which is a good reducing agent. In iodometry it is quantitatively oxidized by iodine to arsenate:
Na3AsO3 + I2 + H2O → Na3AsO4 + 2I- + 2H+
Direction of this reaction depends on pH - in acidic solutions As(V) is able to oxidize iodides to iodine. To guarantee correct pH of the solution we will add solution of sodium bicarbonate NaHCO3.
Interestingly, when using As2O3 as a standard substance in other types of redox titrations, we often add small amount of iodide or iodate to speed up the reaction. For obvious reasons in the case of iodometric titration we don't have to.
Procedure to follow:
Weight exactly about 0.15-0.20g of dry arsenic trioxide and transfer it to Erlenmayer flask.
Add 10 mL of 1M sodium hydroxide solution and dissolve solid.
Add a drop of phenolphthalein solution.
Neutralize with 0.5M sulfuric acid, adding several drops of excess acid after solution loses its color.
Add slowly (to not cause the solution to foam up) 50 mL of 2% NaHCO3 solution.
Add 5 mL of the starch solution.
Titrate swirling the flask, until a blue color persists for 20 seconds.
To calculate iodine solution concentration use EBAS - stoichiometry calculator. Download iodine standardization against arsenic trioxide reaction file, open it with the free trial version of the stoichiometry calculator.
Note, that to be consistent with the use of arsenic trioxide and its molar mass, reaction equation is not the one shown above, but
As2O3 + 2I2 + 5H2O → 2AsO43- + 4I- + 10H+
These are equivalent. Enter arsenic troxide mass in the upper (input) frame in the mass edit field above As2O3 formula. Click n=CV button below iodine in the output frame, enter volume of the solution used, read solution concentration
Potentiometric titrations
There are many redox reagents used in redox titrations. To list a few - potassium permanganate is used for determination of Fe2+, H2O2 and oxalic acid. Potassium dichromate for determination of Fe2+ and Cu in CuCl. Bromate is used for tin and phenol, iodides (titrated with sodium thiosulfate) for H2O2 and Cu2+. Cerium (IV) can be used to determine ferrocyanides and nitrites. There are also many other methods.
Changing property of the solution is its redox potential.
Commonly used indicators are substances that can exist in two forms - oxidized and reduced - that differ in color. Potential at which the substance changes color must be such that the change occurs close to the equivalence point. Examples of such substances are ferroin, diphenylamine or nile blue. Sometimes indicators that are oxidized irreversibly are used. However, in most popular redox titrations there is no need for a special indicator - permanganate has strong color by itself, iodine gives strong color when combined with starch, so their presence or disappearance can be easily detected without additional indicators.
However, there are also important differences. The most obvious one is - while the general idea that observed color depends on the ratio of concentrations of both reduced and oxidized forms still holds, ratio of concentrations is not pH dependent, but redox potential dependent. We can easily calculate ratio of the concentrations of both forms using Nernst equation:
Let's assume - as we did in the case of pH indicators - that for the complete color change we have to move from 10:1 to 1:10 concentration ratio. That means we have to move from the potential
at 25 °C (more precisely it should be 118.2 mV, but as we started with an approximate rule 10:1 to 1:10, such accuracy is not necessary). This is a useful rule of thumb - 120 mV will be enough always. For many indicators reaction requires 2 electrons, so 60 mV change is enough for the observable color change.
Table below contains some of the popular redox indicators. Note, that reduced forms of many indicators are colorless - that means, that indicator concentration plays important role. Also note, that many of these substances are weak acids/bases, thus formal potentials of their reactions can depend on the solution pH. Some of these substances are even used as pH indicators, so their color depends both on the pH and redox potential of the system, which makes selecting them even more complicated.
Interestingly, in the case of three popular potentiometric titrations we usually don't use redox indicators, but specific indicators, that work only in the case of these methods.
In the case of permanganometry there is no need for indicator - small excess of permanganate is immediately visible, as the permanganate itself has a very strong color. As we need some excess of the titrant, it makes sense to start with a blank test, to check what volume of excess titrant has to be added before the color change can be spotted.
In the case of iodometric titration, we use starch. Free iodine adsorbs at the starch surface, changing its color to blue. Depending on the titration type (and titrant) starch will either allow determination of the first traces of excess iodine, or determination of the moment when last traces of iodine disappear. In the latter case it is important to add starch close to the endpoint, as product of the iodine-starch reaction created when iodine concentration is high is relatively stable. Iodine itself is colored and its solutions are yellow, but intensity of the color is usually too low to be useful for endpoint detection.
In the case of bromine titration we can use methyl orange as an indicator - once the excess free bromine appears in the solution, it will oxidize the indicator and solution turns colorless. This is an example of application of irreversible redox indicator.
If you want to select an indicator for your method, you can try approach similar to that described in the acid-base titration end point detection section - calculate redox potential of your system for 99.9% and 100.1% titration and choose an indicator that changes color between these values.